enow.com Web Search

  1. Ad

    related to: nist calibration standard for water pressure

Search results

  1. Results from the WOW.Com Content Network
  2. International Temperature Scale of 1990 - Wikipedia

    en.wikipedia.org/wiki/International_Temperature...

    There are often small differences between measurements calibrated per ITS-90 and thermodynamic temperature.For instance, precise measurements show that the boiling point of VSMOW water under one standard atmosphere of pressure is actually 373.1339 K (99.9839 °C) when adhering strictly to the two-point definition of thermodynamic temperature.

  3. Standard temperature and pressure - Wikipedia

    en.wikipedia.org/wiki/Standard_temperature_and...

    This standard is also called normal temperature and pressure (abbreviated as NTP). However, a common temperature and pressure in use by NIST for thermodynamic experiments is 298.15 K (25 °C, 77 °F) and 1 bar (14.5038 psi, 100 kPa).

  4. Triple point - Wikipedia

    en.wikipedia.org/wiki/Triple_point

    A typical phase diagram.The solid green line applies to most substances; the dashed green line gives the anomalous behavior of water. In thermodynamics, the triple point of a substance is the temperature and pressure at which the three phases (gas, liquid, and solid) of that substance coexist in thermodynamic equilibrium. [1]

  5. Water (data page) - Wikipedia

    en.wikipedia.org/wiki/Water_(data_page)

    In the following table, material data are given with a pressure of 611.7 Pa (equivalent to 0.006117 bar). Up to a temperature of 0.01 °C, the triple point of water, water normally exists as ice, except for supercooled water, for which one data point is tabulated here. At the triple point, ice can exist together with both liquid water and vapor.

  6. Standard (metrology) - Wikipedia

    en.wikipedia.org/wiki/Standard_(metrology)

    Secondary standards are calibrated with reference to a primary standard. [2] The third level of standard, a standard which is periodically calibrated against a secondary standard, is known as a working standard. [2] Working standards are used for the calibration of commercial and industrial measurement equipment.

  7. Colorado Engineering Experiment Station, Inc. - Wikipedia

    en.wikipedia.org/wiki/Colorado_Engineering...

    This scale-up calibration process is repeated regularly in accordance with NIST quality procedures. Flow meter calibration end users have the option to pay NIST to supervise calibrations; these calibrations qualify as NIST calibrations. [7]

  8. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  9. Vapor pressures of the elements (data page) - Wikipedia

    en.wikipedia.org/wiki/Vapor_pressures_of_the...

    The temperature at standard pressure should be equal to the normal boiling point, but due to the considerable spread does not necessarily have to match values reported elsewhere. log refers to log base 10 (T/K) refers to temperature in Kelvin (K) (P/Pa) refers to pressure in Pascal (Pa)

  1. Ad

    related to: nist calibration standard for water pressure