enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Absorbance - Wikipedia

    en.wikipedia.org/wiki/Absorbance

    Nevertheless, the absorbance unit or AU is commonly used in ultraviolet–visible spectroscopy and its high-performance liquid chromatography applications, often in derived units such as the milli-absorbance unit (mAU) or milli-absorbance unit-minutes (mAU×min), a unit of absorbance integrated over time. [6] Absorbance is related to optical ...

  3. Molar absorption coefficient - Wikipedia

    en.wikipedia.org/wiki/Molar_absorption_coefficient

    The SI unit of molar absorption coefficient is the square metre per mole (m 2 /mol), but in practice, quantities are usually expressed in terms of M −1 ⋅cm −1 or L⋅mol −1 ⋅cm −1 (the latter two units are both equal to 0.1 m 2 /mol). In older literature, the cm 2 /mol is sometimes used; 1 M −1 ⋅cm −1 equals 1000 cm 2 /mol.

  4. Absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Absorption_spectroscopy

    The most straightforward approach to absorption spectroscopy is to generate radiation with a source, measure a reference spectrum of that radiation with a detector and then re-measure the sample spectrum after placing the material of interest in between the source and detector. The two measured spectra can then be combined to determine the ...

  5. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    Scientists use this instrument to measure the amount of compounds in a sample. If the compound is more concentrated more light will be absorbed by the sample; within small ranges, the Beer–Lambert law holds and the absorbance between samples vary with concentration linearly. In the case of printing measurements two alternative settings are ...

  6. Atomic absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Atomic_absorption_spectroscopy

    Step 4: Measurement and Analysis:** The light intensity before and after passing through the sample is measured by a detector. The difference in intensity is directly proportional to the concentration of the analyte in the sample, following the Beer-Lambert law: * **A = εcl**, where: * A is the absorbance measured.

  7. Specific ultraviolet absorbance - Wikipedia

    en.wikipedia.org/.../Specific_ultraviolet_absorbance

    Specific ultraviolet absorbance (SUVA) is the absorbance of ultraviolet light in a water sample at a specified wavelength that is normalized for dissolved organic carbon (DOC) concentration. [1] Specific UV absorbance (SUVA) wavelengths have analytical uses to measure the aromatic character of dissolved organic matter by detecting density of ...

  8. UV detectors - Wikipedia

    en.wikipedia.org/wiki/UV_detectors

    A schematic of the optical systems is shown in Figure 1. The variable UV-Vis absorbance detector's optical bench is showing how the flow cell is positioned after the optical system, including the monochromator, which typically has a physical slit and a moving grating, so it is illuminated by a selected wavelength, reaching a photo-diode.

  9. Colorimeter (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Colorimeter_(chemistry)

    A colorimeter is a device used in colorimetry that measures the absorbance of particular wavelengths of light by a specific solution. [1] [2] It is commonly used to determine the concentration of a known solute in a given solution by the application of the Beer–Lambert law, which states that the concentration of a solute is proportional to the absorbance.