enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Attenuator (electronics) - Wikipedia

    en.wikipedia.org/wiki/Attenuator_(electronics)

    Z in = the impedance seen looking into the input port when Z Load is connected to the output port. Z in is a function of the load impedance. Z out = the impedance seen looking into the output port when Z s is connected to the input port. Z out is a function of the source impedance. V s = source open circuit or unloaded voltage.

  3. Characteristic impedance - Wikipedia

    en.wikipedia.org/wiki/Characteristic_impedance

    A surge of energy on a finite transmission line will see an impedance of prior to any reflections returning; hence surge impedance is an alternative name for characteristic impedance. Although an infinite line is assumed, since all quantities are per unit length, the “per length” parts of all the units cancel, and the characteristic ...

  4. Π pad - Wikipedia

    en.wikipedia.org/wiki/Π_pad

    A Π-pad attenuator formed from two symmetrical L sections. Because of the symmetry, R 1 = R 3 in this case. For an attenuator, Z and Y are simple resistors and γ becomes the image parameter attenuation (that is, the attenuation when terminated with the image impedances) in nepers. A Π pad can be viewed as being two L sections back-to-back as ...

  5. T pad - Wikipedia

    en.wikipedia.org/wiki/T_pad

    A T-pad attenuator formed from two symmetrical L sections. Because of the symmetry, R 1 = R 3 in this case. For an attenuator, Z and Y are simple resistors and γ becomes the image parameter attenuation (that is, the attenuation when terminated with the image impedances) in nepers. A T pad can be viewed as being two L sections back-to-back as ...

  6. Mathematical descriptions of opacity - Wikipedia

    en.wikipedia.org/wiki/Mathematical_descriptions...

    An electromagnetic wave propagating in the +z-direction is conventionally described by the equation: (,) = ⁡ [()], where E 0 is a vector in the x-y plane, with the units of an electric field (the vector is in general a complex vector, to allow for all possible polarizations and phases);

  7. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    Practical impedance-matching devices will generally provide best results over a specified frequency band. The concept of impedance matching is widespread in electrical engineering, but is relevant in other applications in which a form of energy, not necessarily electrical, is transferred between a source and a load, such as in acoustics or optics.

  8. RLC circuit - Wikipedia

    en.wikipedia.org/wiki/RLC_circuit

    α is called the neper frequency, or attenuation, and is a measure of how fast the transient response of the circuit will die away after the stimulus has been removed. Neper occurs in the name because the units can also be considered to be nepers per second, neper being a logarithmic unit of attenuation. ω 0 is the angular resonance frequency. [3]

  9. Propagation constant - Wikipedia

    en.wikipedia.org/wiki/Propagation_constant

    In telecommunications, the term attenuation constant, also called attenuation parameter or attenuation coefficient, is the attenuation of an electromagnetic wave propagating through a medium per unit distance from the source. It is the real part of the propagation constant and is measured in nepers per metre.