This circuit is used for the general case, all T-pads, all pi-pads and L-pads when the source impedance is greater than or equal to the load impedance. The L-pad computation assumes that port 1 has the highest impedance. If the highest impedance happens to be the output port, then use this figure. Unique resistor designations for Tee, Pi and L ...
The input impedance of an infinite line is equal to the characteristic impedance since the transmitted wave is never reflected back from the end. Equivalently: The characteristic impedance of a line is that impedance which, when terminating an arbitrary length of line at its output, produces an input impedance of equal value. This is so because ...
An electromagnetic wave propagating in the +z-direction is conventionally described by the equation: (,) = [()], where E 0 is a vector in the x-y plane, with the units of an electric field (the vector is in general a complex vector, to allow for all possible polarizations and phases);
The attenuation in the signal of ground motion intensity plays an important role in the assessment of possible strong groundshaking. A seismic wave loses energy as it propagates through the earth (seismic attenuation). This phenomenon is tied into the dispersion of the seismic energy with the distance. There are two types of dissipated energy:
An attenuator is a form of a two-port network with a generator connected to one port and a load connected to the other. In all of the circuits given below it is assumed that the generator and load impedances are purely resistive (though not necessarily equal) and that the attenuator circuit is required to perfectly match to these.
The equations above find the impedance and loss for an attenuator with given resistor values. The usual requirement in a design is the other way around – the resistor values for a given impedance and loss are needed. These can be found by transposing and substituting the last two equations above; If = =
α is called the neper frequency, or attenuation, and is a measure of how fast the transient response of the circuit will die away after the stimulus has been removed. Neper occurs in the name because the units can also be considered to be nepers per second, neper being a logarithmic unit of attenuation. ω 0 is the angular resonance frequency. [3]
On-die termination (ODT) or Digitally Controlled Impedance (DCI [4]) is the technology where the termination resistor for impedance matching in transmission lines is located within a semiconductor chip, instead of a separate, discrete device mounted on a circuit board. The closeness of the termination from the receiver shorten the stub between ...