enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Integral nonlinearity - Wikipedia

    en.wikipedia.org/wiki/Integral_nonlinearity

    In DACs, it is a measure of the deviation between the ideal output value and the actual measured output value for a certain input code. In ADCs, it is the deviation between the ideal input threshold value and the measured threshold level of a certain output code. This measurement is performed after offset and gain errors have been compensated. [1]

  3. Differential nonlinearity - Wikipedia

    en.wikipedia.org/wiki/Differential_nonlinearity

    Differential non-linearity is a measure of the worst-case deviation from the ideal 1 LSB step. For example, a DAC with a 1.5 LSB output change for a 1 LSB digital code change exhibits 1⁄2 LSB differential non-linearity. Differential non-linearity may be expressed in fractional bits or as a percentage of full scale.

  4. Nonlinear control - Wikipedia

    en.wikipedia.org/wiki/Nonlinear_control

    Even if the plant is linear, a nonlinear controller can often have attractive features such as simpler implementation, faster speed, more accuracy, or reduced control energy, which justify the more difficult design procedure. An example of a nonlinear control system is a thermostat-controlled heating system. A building heating system such as a ...

  5. Group delay and phase delay - Wikipedia

    en.wikipedia.org/wiki/Group_delay_and_phase_delay

    The degree of nonlinearity of the phase indicates the deviation of the group delay from a constant value. The differential group delay is the difference in propagation time between the two eigenmodes X and Y polarizations. Consider two eigenmodes that are the 0° and 90° linear polarization states. If the state of polarization of the input ...

  6. Nonlinear system identification - Wikipedia

    en.wikipedia.org/wiki/Nonlinear_system...

    System identification is a method of identifying or measuring the mathematical model of a system from measurements of the system inputs and outputs. The applications of system identification include any system where the inputs and outputs can be measured and include industrial processes, control systems, economic data, biology and the life sciences, medicine, social systems and many more.

  7. Error analysis for the Global Positioning System - Wikipedia

    en.wikipedia.org/wiki/Error_analysis_for_the...

    Inconsistencies of atmospheric conditions affect the speed of the GPS signals as they pass through the Earth's atmosphere, especially the ionosphere.Correcting these errors is a significant challenge to improving GPS position accuracy.

  8. Sensitivity (control systems) - Wikipedia

    en.wikipedia.org/wiki/Sensitivity_(control_systems)

    1.1 Sensitivity function as a measure of robustness to parameter variation 1.2 Sensitivity function as a measure of disturbance attenuation 2 Sensitivity peak and sensitivity circle

  9. Setpoint (control system) - Wikipedia

    en.wikipedia.org/wiki/Setpoint_(control_system)

    Departure of such a variable from its setpoint is one basis for error-controlled regulation using negative feedback for automatic control. [3] A setpoint can be any physical quantity or parameter that a control system seeks to regulate, such as temperature, pressure, flow rate, position, speed, or any other measurable attribute.