The Bradford protein assay (also known as the Coomassie protein assay) was developed by Marion M. Bradford in 1976. [1] It is a quick and accurate [2] spectroscopic analytical procedure used to measure the concentration of protein in a solution. The reaction is dependent on the amino acid composition of the measured proteins.
The Lowry protein assay is a biochemical assay for determining the total level of protein in a solution. The total protein concentration is exhibited by a color change of the sample solution in proportion to protein concentration, which can then be measured using colorimetric techniques .
Bradford protein assay: Detection in the range of ~1 mg/mL; Biuret Test Derived Assays: Bicinchoninic acid assay (BCA assay): Detection down to 0.5 μg/mL; Lowry Protein assay: Detection in the range of 0.01–1.0 mg/mL; Fluorescamine: Quantifies proteins and peptides in solution if primary amine are present in the amino acids
BCA protein assay in a 96 well plate. The bicinchoninic acid assay (BCA assay), also known as the Smith assay, after its inventor, Paul K. Smith at the Pierce Chemical Company, [1] now part of Thermo Fisher Scientific, is a biochemical assay for determining the total concentration of protein in a solution (0.5 μg/mL to 1.5 mg/mL), similar to Lowry protein assay, Bradford protein assay or ...
An assay (analysis) is never an isolated process, as it must be accompanied with pre- and post-analytic procedures. Both the communication order (the request to perform an assay plus related information) and the handling of the specimen itself (the collecting, documenting, transporting, and processing done before beginning the assay) are pre-analytic steps.
As of September 2015, his 1951 paper in the Journal of Biological Chemistry [5] describing the protein assay was still the most-highly cited paper in history, with more than 310,000 citations, [6] although Lowry stated it was not the most important paper he had ever written.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]