Radiant systems, encompassing both heating and cooling, transfer heat or coolness directly through surfaces, such as floors, ceilings, or walls, instead of relying on forced-air systems. These systems are broadly categorized into three types: [19] thermally activated building systems (TABS), [20] embedded surface systems, and radiant ceiling ...
AMCA Publication 503 - Fire, Ceiling (Radiation), Smoke, and Fire/Smoke Damper Application Manual details information for individuals that design, purchase, or specify systems in which fire and/or smoke is a factor. Includes much of the information not found in the companion guide, AMCA Publication 502.
The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...
The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.
For premium support please call: 800-290-4726 more ways to reach us
radiant floor A type of radiant heating system where the building floor contains channels or tubes through which hot fluids such as air or water are circulated. The whole floor is evenly heated. Thus, the room is heated from the bottom up. Radiant floor heating eliminates the draft and dust problems associated with forced air heating systems ...
A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.
Hydronic radiant floor heating systems use a boiler or district heating to heat water and a pump to circulate the hot water in plastic pipes installed in a concrete slab. The pipes, embedded in the floor, carry heated water that conducts warmth to the surface of the floor, where it broadcasts heat energy to the room above.