    This rating does not apply to all generator set models. Typical application - where the generator is the sole source of power for say a remote mining or construction site, fairground, festival etc. Base Load (Continuous) Rating based on: Applicable for supplying power continuously to a constant load up to the full output rating for unlimited ...

  3. Rating plate - Wikipedia

    en.wikipedia.org/wiki/Rating_plate

    The plate frequently contains the names of the machine and its manufacturer, so the rating plate is often called a name plate (hence the term "nameplate capacity" for a generator), although many devices carry separate nameplates and rating plates. [1] For an electric machine, the power rating is the number on its rating plate and corresponds to ...

  4. Orders of magnitude (power) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(power)

    1.00 × 10 4 W eco: average power consumption per person in the United States in 2008 (87,216 kWh/year) 1.4 × 10 4 W tech: average power consumption of an electric car on EPA's Highway test schedule [25] [26] 1.45 × 10 4 W astro: power per square metre received from the Sun at Mercury's orbit at perihelion: 1.6–3.2 × 10 4 W

  5. Nameplate capacity - Wikipedia

    en.wikipedia.org/wiki/Nameplate_capacity

    Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others.

  6. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its service life is reduced to less than half for continued operation at this level. [4] [10] The service factor is defined in the ANSI/NEMA MG 1 standard, [11] and is generally used in the United States. [12]

  7. Watt - Wikipedia

    en.wikipedia.org/wiki/Watt

    The watt (symbol: W) is the unit of power or radiant flux in the International System of Units (SI), equal to 1 joule per second or 1 kg⋅m 2 ⋅s −3. [1] [2] [3] It is used to quantify the rate of energy transfer.

  8. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    An engine–generator is the combination of an electrical generator and an engine (prime mover) mounted together to form a single piece of equipment. This combination is also called an engine–generator set or a gen-set. In many contexts, the engine is taken for granted and the combined unit is simply called a generator. An engine–generator ...

  9. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...