Search results
Results from the WOW.Com Content Network
To overcome this, a second pair of resistors R′ 1 and R′ 2 form a second pair of arms of the bridge (hence 'double bridge') and are connected to the inner potential terminals of R s and R x (identified as P 2 and P′ 2 in the diagram). The detector D is connected between the junction of R 1 and R 2 and the junction of R′ 1 and R′ 2. [2]
Linear potential sweep. Voltammetry is a category of electroanalytical methods used in analytical chemistry and various industrial processes. In voltammetry, information about an analyte is obtained by measuring the current as the potential is varied.
Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...
Data acquisition is the process of sampling signals that measure real-world physical conditions and converting the resulting samples into digital numeric values that can be manipulated by a computer. Data acquisition systems, abbreviated by the acronyms DAS, DAQ, or DAU, typically convert analog waveforms into digital values for processing.
The Kelvin water dropper, invented by Scottish scientist William Thomson (Lord Kelvin) in 1867, [1] is a type of electrostatic generator. Kelvin referred to the device as his water-dropping condenser. The apparatus is variously called the Kelvin hydroelectric generator, the Kelvin electrostatic generator, or Lord Kelvin's thunderstorm.
The final stage of a Kelvin–Varley divider is just a Kelvin divider. For a decade divider, there will be ten equal value resistors. Let the value of each resistor be R n Ohms. The input impedance of the entire string will be 10 R n. Alternatively, the last stage can be a two resistor bridge tap.
The data below tabulates standard electrode potentials (E°), in volts relative to the standard hydrogen electrode (SHE), at: Temperature 298.15 K (25.00 °C; 77.00 °F); Effective concentration (activity) 1 mol/L for each aqueous or amalgamated (mercury-alloyed) species; Unit activity for each solvent and pure solid or liquid species; and
A Maxwell-Wien bridge. A Maxwell bridge is a modification to a Wheatstone bridge used to measure an unknown inductance (usually of low Q value) in terms of calibrated resistance and inductance or resistance and capacitance. [1] When the calibrated components are a parallel resistor and capacitor, the bridge is known as a Maxwell bridge.