    However, opening pressures are notoriously unreliable when measured in the seated position. Therefore, patients will ideally lie on their side if practitioners need to measure opening pressure. [citation needed] Reinsertion of the stylet may decrease the rate of post lumbar puncture headaches. [15]

  3. Non-invasive measurement of intracranial pressure - Wikipedia

    en.wikipedia.org/wiki/Non-invasive_measurement...

    The TDTD method uses Doppler ultrasound to translate the pressure balance principle of blood pressure measurement with a sphygmomanometer to the measurement of ICP. The ophthalmic artery (OA), a unique vessel with intracranial and extracranial segments, is used as a pressure sensor and as a natural pair of scales for absolute ICP value in mmHg ...

  4. Intracranial pressure - Wikipedia

    en.wikipedia.org/wiki/Intracranial_pressure

    Intracranial pressure (ICP) is the pressure exerted by fluids such as cerebrospinal fluid (CSF) inside the skull and on the brain tissue. ICP is measured in millimeters of mercury and at rest, is normally 7–15 mmHg for a supine adult. This equals to 9–20 cmH 2 O, which is a common scale used in lumbar punctures. [1]

  5. Idiopathic intracranial hypertension - Wikipedia

    en.wikipedia.org/wiki/Idiopathic_intracranial...

    Lumbar puncture is performed to measure the opening pressure, as well as to obtain cerebrospinal fluid (CSF) to exclude alternative diagnoses. If the opening pressure is increased, CSF may be removed for transient relief (see below). [8] The CSF is examined for abnormal cells, infections, antibody levels, the glucose level, and protein levels.

  6. Intracranial pressure monitoring - Wikipedia

    en.wikipedia.org/wiki/Intracranial_pressure...

    Under normal conditions, regular movements such as leaning forward, normal heartbeat and breathing can cause changes to the ICP. Intracranial monitoring accounts for this by averaging measurements over 30 minutes in non-comatose patients. Readings between 7-15mmHg are considered normal in an adult, 3-7mmHg in children, and 1.4-6mmHg in infants. [4]

  7. Queckenstedt's maneuver - Wikipedia

    en.wikipedia.org/wiki/Queckenstedt's_maneuver

    Given normal anatomy, the intracranial pressure will be reflected as a rapidly rising pressure measured from the lumbar needle, within 10–12 seconds. If there is a stenosis in the spine, there will be a damped, delayed response in the lumbar pressure, thus a positive Queckenstedt's maneuver.

  8. Instruments used in general medicine - Wikipedia

    en.wikipedia.org/wiki/Instruments_used_in...

    to measure concentration of glucose in blood: Haemodialysis machine: to remove toxic materials from the blood that are generally removed by the kidneys; used in case of kidney failure [3] Hypodermic needle / Syringe: for injections and aspiration of blood or fluid from the body Infection control equipment

  9. CSF tap test - Wikipedia

    en.wikipedia.org/wiki/CSF_tap_test

    The CSF tap test, sometimes lumbar tap test or Miller Fisher Test, is a medical test that is used to decide whether shunting of cerebrospinal fluid (CSF) would be helpful in a patient with suspected normal pressure hydrocephalus (NPH).