Search results
Results from the WOW.Com Content Network
The Henderson–Hasselbalch equation relates the pH of a solution containing a mixture of the two components to the acid dissociation constant, K a of the acid, and the concentrations of the species in solution. [6] Simulated titration of an acidified solution of a weak acid (pK a = 4.7) with alkali
In particular, the pH of a solution can be predicted when the analytical concentration and pK a values of all acids and bases are known; conversely, it is possible to calculate the equilibrium concentration of the acids and bases in solution when the pH is known. These calculations find application in many different areas of chemistry, biology ...
K 1, K 2 and DIC each have units of a concentration, e.g. mol/L. A Bjerrum plot is obtained by using these three equations to plot these three species against pH = −log 10 [H +] eq, for given K 1, K 2 and DIC. The fractions in these equations give the three species' relative proportions, and so if DIC is unknown, or the actual concentrations ...
Speciation of ions refers to the changing concentration of varying forms of an ion as the pH of the solution changes. [1]The ratio of acid, AH and conjugate base, A −, concentrations varies as the difference between the pH and the pK a varies, in accordance with the Henderson-Hasselbalch equation.
The concentration of water, [H 2 O], is omitted by convention, which means that the value of K w differs from the value of K eq that would be computed using that concentration. The value of K w varies with temperature, as shown in the table below. This variation must be taken into account when making precise measurements of quantities such as pH.
At 298 K, 1 pH unit is approximately equal to 59 mV. [2] When the electrode is calibrated with solutions of known concentration, by means of a strong acid–strong base titration, for example, a modified Nernst equation is assumed. = + [] where s is an empirical slope factor.
The pH can be calculated using an ICE table. Note that in this example, we are assuming that the acid is not very weak, and that the concentration is not very dilute, so that the concentration of [OH −] ions can be neglected. This is equivalent to the assumption that the final pH will be below about 6 or so. See pH calculations for more details.
The pH meter is usually calibrated with buffer solutions at known pH values before starting the titration. The ionic strength can be kept constant by judicious choice of acid and base. For instance, HCl titrated with NaOH of approximately the same concentration will replace H + with an ion (Na + ) of the same charge at the same concentration ...