A manifold pressure regulating shut-off valve (MPRSOV) restricts the flow as necessary to maintain the desired pressure for downstream systems. A certain minimum supply pressure is needed to drive the air through the system, but it is desired to use as low a supply pressure as possible, because the energy the engine uses to compress the bleed ...
A high-integrity pressure protection system (HIPPS) is a type of safety instrumented system (SIS) designed to prevent over-pressurization of a plant, such as a chemical plant or oil refinery. The HIPPS will shut off the source of the high pressure before the design pressure of the system is exceeded, thus preventing loss of containment through ...
A water pressure regulating valve limits inflow by dynamically changing the valve opening so that when less pressure is on the outside, the valve opens up fully, and too much pressure on the outside causes the valve to shut. In a no pressure situation, where water could flow backwards, it won't be impeded. A water pressure regulating valve does ...
A shutdown valve (also referred to as SDV or emergency shutdown valve, ESV, ESD, or ESDV; or safety shutoff valve) is an actuated valve designed to stop the flow of a hazardous fluid upon the detection of a dangerous event. This provides protection against possible harm to people, equipment or the environment.
Project management office: The Project management office in a business or professional enterprise is the department or group that defines and maintains the standards of process, generally related to project management, within the organization. The PMO strives to standardize and introduce economies of repetition in the execution of projects.
Valves and their types and identifications (e.g. isolation, shutoff, relief and safety valves, valve interlocks) Control inputs and outputs (sensors and final elements, interlocks) Miscellaneous - vents, drains, flanges, special fittings, sampling lines, reducers and swages; Interfaces for class changes; Computer control system
The analysis ensures that two levels of protection are provided to mitigate each undesirable event. For example, for a pressure vessel subjected to over-pressure the primary protection would be a PSH (pressure switch high) to shut off inflow to the vessel, secondary protection would be provided by a pressure safety valve (PSV) on the vessel. [8]