enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    Small pumps have tanks that range from 2 to 4 liters (0.5 to 1 gallon) and are usually supported using the flanges on their tanks or simply placed upon the floor. A plastic impeller in a molded volute at the bottom of the pump provides the pumping action; this impeller is connected to the motor via a metal shaft that extends downwards from the ...

  3. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    A duplex steam pump has two sets of steam and water cylinders. They are not physically connected but the steam valves on the first pump are operated by the movement of the second pump's piston rod, and vice versa. The result is that there are no "dead spots" and the pump is always self-starting. [2]

  4. Gree Electric - Wikipedia

    en.wikipedia.org/wiki/Gree_Electric

    Gree Electric is a majority state-owned enterprise, primarily by the city of Zhuhai. [9] As of 31 December 2015, the largest shareholder of Gree Electric was Gree Group; it was followed by Hebei Jinghai Investment Guarantee (for 8.91%), China Securities Finance (for 2.99%), Central Huijin Investment (for 1.40%).

  5. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  6. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Condensing boilers are water heaters typically used for heating systems that are fueled by gas or oil. When operated in the correct circumstances, a heating system can achieve high efficiency (greater than 90% on the higher heating value) by condensing water vapour found in the exhaust gases in a heat exchanger to preheat the circulating water.

  7. Surface condenser - Wikipedia

    en.wikipedia.org/wiki/Surface_condenser

    At the bottom of the shell, where the condensate collects, an outlet is installed. In some designs, a sump (often referred to as the hotwell) is provided. Condensate is pumped from the outlet or the hotwell for reuse as boiler feedwater. For most water-cooled surface condensers, the shell is under [partial] vacuum during normal operating ...

  8. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    At $1 per therm, the cost of the gas would be about 40 cents. In comparison, a typical 230 L (60 US gal) tank electric water heater has a 4.5 kW (15,000 BTU/h) heating element, which at 100% efficient results in a heating time of about 2.34 hours. At $0.16/kWh the electricity would cost $1.68.

  9. Natural-gas condensate - Wikipedia

    en.wikipedia.org/wiki/Natural-gas_condensate

    The natural gas condensate is also called condensate, or gas condensate, or sometimes natural gasoline because it contains hydrocarbons within the gasoline boiling range, and is also referred to by the shortened name condy by many workers on gas installations. Raw natural gas used to create condensate may come from any type of gas well such as ...