enow.com Web Search

  1. Ads

    related to: 200 amp 120/208 volt 3 phase meter socket with a bypass

Search results

  1. Results from the WOW.Com Content Network
  2. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    This setup produces three different voltages: If the voltage between the center tap (neutral) and each of the top and bottom taps (phase and anti-phase) is 120 V (100%), the voltage across the phase and anti-phase lines is 240 V (200%), and the neutral to "high leg" voltage is ≈ 208 V (173%).

  3. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    The type 15 plug and socket has 3 round pins of 4 mm diameter, plus 2 flat pins (for L2 and L3). It is designed for three phase applications and is rated at 10 A, 250 V/440 V. The socket will also accept types 11 and 12 plugs, and the Europlug. The type 25 plug and socket has 3 rectangular pins, 4 mm x 5 mm, plus 2 flat pins (for L2 and L3).

  4. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA L6 connectors are rated for a maximum of 250 volts. They are intended for two-pole, three wire, line-line-earth (or hot-hot-ground) circuits with a nominal supply voltage of 208 or 240 volts, depending on phase configuration. The L6 connector does not provide a neutral connection.

  5. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The most common ratings are 16 A, 32 A and 63 A, with 125 A less common. Construction sites in central Europe have most of their higher power cabling setup with this three phase socket type as the single phase to neutral voltage of 230 V is available for other devices. So called power splitters with this connector as a 3 phase inlet and 3 ...

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current. That is why we calculate 130 V × √ 3 = 225 V. A ...

  7. AC power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/AC_power_plugs_and_sockets

    Again, the three-phase power socket is compatible with single-phase plugs, either of 10 A or 16 A ratings: [57] The type 25 plug has three rectangular pins of the same dimensions as type 23, plus two rectangular pins of the same dimensions as type 15. The corresponding type 25 socket is recessed and will accept plugs of types 11, 12, 15, 21, 23 ...

  1. Ads

    related to: 200 amp 120/208 volt 3 phase meter socket with a bypass