The thermal conductivity of a material is a measure of its ability to conduct heat. It is commonly denoted by , , or and is measured in W·m −1 ·K −1. Heat transfer occurs at a lower rate in materials of low thermal conductivity than in materials of high thermal conductivity.
Very high thermal conductivity measurements up to 22,600 w m −1 K −1 were reported by Fenton, E.W., Rogers, J.S. and Woods, S.D. in reference 570 on page 1458, 41, 2026–33, 1963. The data is listed on pages 6 through 8 and graphed on page 1 where Fenton and company are on curves 63 and 64.
The average thermal insulance of the "bridged" layer depends upon the fraction of the area taken up by the mortar in comparison with the fraction of the area taken up by the light concrete blocks. To calculate thermal transmittance when there are "bridging" mortar joints it is necessary to calculate two quantities, known as R max and R min.
In most countries the properties of specific materials (such as insulation) are indicated by the thermal conductivity, sometimes called a k-value or lambda-value (lowercase λ). The thermal conductivity (k-value) is the ability of a material to conduct heat; hence, the lower the k-value, the better the material is for insulation.
A 2008 review paper written by Philips researcher Clemens J. M. Lasance notes that: "Although there is an analogy between heat flow by conduction (Fourier's law) and the flow of an electric current (Ohm’s law), the corresponding physical properties of thermal conductivity and electrical conductivity conspire to make the behavior of heat flow ...
The heat generated dissipates into the sample on both sides of the sensor, at a rate depending on the thermal transport properties of the material. By recording temperature vs. time response in the sensor, the thermal conductivity, thermal diffusivity and specific heat capacity of the material can be calculated.
In-situ thermal insulation measurement according to ASTM C0141, applying a heat flux sensor to a boiler wall. On-site heat flux measurements are often focused on testing the thermal transport properties of for example pipes, tanks, ovens and boilers, by calculating the heat flux q or the apparent thermal conductivity.
EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...