enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Infrared gas analyzer - Wikipedia

    en.wikipedia.org/wiki/Infrared_gas_analyzer

    Infrared gas analyzers usually have two chambers, one is a reference chamber while the other chamber is a measurement chamber. Infrared light is emitted from some type of source on one end of the chamber, passes through a series of chambers that contains given quantities of the various gases in question.

  3. Nondispersive infrared sensor - Wikipedia

    en.wikipedia.org/wiki/Nondispersive_infrared_sensor

    A nondispersive infrared sensor (or NDIR sensor) is a simple spectroscopic sensor often used as a gas detector.It is non-dispersive in the fact that no dispersive element (e.g a prism or diffraction grating as is often present in other spectrometers) is used to separate out (like a monochromator) the broadband light into a narrow spectrum suitable for gas sensing.

  4. Infrared open-path detector - Wikipedia

    en.wikipedia.org/wiki/Infrared_open-path_detector

    The choice of infrared wavelengths used for the measurement largely defines the detector's suitability for a particular applications. Not only must the target gas (or gases) have a suitable absorption spectrum, the wavelengths must lie within a spectral window so the air in the beam path is itself transparent. These wavelength regions have been ...

  5. Infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Infrared_spectroscopy

    Infrared spectroscopy is a simple and reliable technique widely used in both organic and inorganic chemistry, in research and industry. It is used in quality control, dynamic measurement, and monitoring applications such as the long-term unattended measurement of CO 2 concentrations in greenhouses and growth chambers by infrared gas analyzers.

  6. Infrared point sensor - Wikipedia

    en.wikipedia.org/wiki/Infrared_point_sensor

    Dual source and dual receivers are used for self compensation of changes in alignment, light source intensity and component efficiency. The transmitted beams from two infrared sources are superimposed onto an internal beam splitter. 50% of the overlapping sample and reference signal is passed through the gas measuring path and reflected back onto the measuring detector.

  7. Fourier-transform infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fourier-transform_infrared...

    Fourier transform infrared spectroscopy (FTIR) [1] is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid, or gas. An FTIR spectrometer simultaneously collects high-resolution spectral data over a wide spectral range.

  8. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    Spectrophotometers designed for the infrared region are quite different because of the technical requirements of measurement in that region. One major factor is the type of photosensors that are available for different spectral regions, but infrared measurement is also challenging because virtually everything emits IR as thermal radiation ...

  9. Absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Absorption_spectroscopy

    The infrared absorption spectrum of NASA laboratory sulfur dioxide ice is compared with the infrared absorption spectra of ices on Jupiter's moon, Io credit NASA, Bernard Schmitt, and UKIRT. Absorption spectroscopy is useful in chemical analysis [5] because of its specificity and its quantitative nature. The specificity of absorption spectra ...