Search results
Results from the WOW.Com Content Network
(G) PVC Water Stops; 1 Code of practice for the provision of water stops. IS 12200 – 1987 2 Procedure for Testing Parts of IS 8543-19 3 Standard Test Methods for Tensile Properties of Plastics. ASTM : D 638-1991 4 Standard Test Methods for Thermoplastic Elastomers-Tension. ASTM : D 412-1992 (H) HYSD BARS; 1 Specifications for HYSD bars.
The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...
In soil science, soil gradation is a classification of a coarse-grained soil that ranks the soil based on the different particle sizes contained in the soil. [1] Soil gradation is an important aspect of soil mechanics and geotechnical engineering because it is an indicator of other engineering properties such as compressibility , shear strength ...
The Atterberg limits are a basic measure of the critical water contents of a fine-grained soil: its shrinkage limit, plastic limit, and liquid limit. Depending on its water content, soil may appear in one of four states: solid, semi-solid, plastic and liquid. In each state, the consistency and behavior of soil are different, and consequently so ...
The Unified Soil Classification System (USCS) is a soil classification system used in engineering and geology to describe the texture and grain size of a soil. The classification system can be applied to most unconsolidated materials, and is represented by a two-letter symbol. Each letter is described below (with the exception of Pt):
A sieve analysis (or gradation test) is a practice or procedure used in geology, civil engineering, [1] and chemical engineering [2] to assess the particle size distribution (also called gradation) of a granular material by allowing the material to pass through a series of sieves of progressively smaller mesh size and weighing the amount of material that is stopped by each sieve as a fraction ...
For free flow, the equation to determine the flow rate is simply Q = CH a n where: Q is flowing rate (ft 3 /s) C is the free-flow coefficient for the flume (see Table 1 below) H a is the head at the primary point of measurement (ft) (See Figure 1 above) n varies with flume size (see Table 1 below) Parshall flume discharge table for free flow ...
where: [2] Q f = total residual flow during the test (gallons per minute); c = discharge coefficient (unitless). This is usually 1.0 if using a diffuser. If using a wand to measure the stagnation pressure, the coefficient value depends on the shape of the flow hydrant orifice.