enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Full load hour - Wikipedia

    en.wikipedia.org/wiki/Full_load_hour

    Full Load hour is a measure of the degree of utilisation of a technical system. [1] [2] [3] Full load hours refer to the time for which a plant would have to be operated at nominal power in order to convert the same amount of electrical work as the plant has actually converted within a defined period of time, during which breaks in operation or partial load operation can also occur.

  3. Electrical load - Wikipedia

    en.wikipedia.org/wiki/Electrical_load

    Load affects the performance of circuits with respect to output voltages or currents, such as in sensors, voltage sources, and amplifiers. Mains power outlets provide an easy example: they supply power at constant voltage, with electrical appliances connected to the power circuit collectively making up the load.

  4. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    The power is measured while varying the resistive load on the module between open and closed circuit. The maximum power measured is the nominal power of the module in Watts. Colloquially, this is also written as "W p"; this format is colloquial as it is outside the standard by adding suffixes to standardized units.

  5. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    A leading power factor signifies that the load is capacitive, as the load supplies reactive power, and therefore the reactive component is negative as reactive power is being supplied to the circuit. If θ is the phase angle between the current and voltage, then the power factor is equal to the cosine of the angle, cos ⁡ θ {\displaystyle ...

  6. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...

  7. Load regulation - Wikipedia

    en.wikipedia.org/wiki/Load_regulation

    is the voltage at maximum load. The maximum load is the one that draws the greatest current, i.e. the lowest specified load resistance (never short circuit); is the voltage at minimum load. The minimum load is the one that draws the least current, i.e. the highest specified load resistance (possibly open circuit for some types of linear ...

  8. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  9. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Some terminations on wiring devices designed only for copper wire would overheat under heavy current load and cause fires when used with aluminium conductors. Revised standards for wire materials and wiring devices (such as the CO/ALR "copper-aluminium-revised" designation) were developed to reduce these problems. While larger sizes are still ...