Results from the WOW.Com Content Network
The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131) [4] The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing ...
The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are normally high pressure units that take suction from a condensate return system and can be of the centrifugal pump type or positive displacement type.
The forced circulation boiler begins the same as a natural circulation boiler, at the feed water pump. Water is introduced into the steam drum and is circulated around the boiler, leaving only as steam. What makes the forced circulation boiler different is its use of a secondary pump that circulates water through the boiler.
The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).
Diagram of a water-tube boiler. Water-tube boiler In this type, tubes filled with water are arranged inside a furnace in a number of possible configurations. Often the water tubes connect large drums, the lower ones containing water and the upper ones steam and water; in other cases, such as a mono-tube boiler, water is circulated by a pump ...
Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Donate
In a natural circulation boiler the circulation is achieved by the difference in density when the water in the boiler is heated. In natural circulation steam boilers the circulation of water is by convection currents, which are set up during the heating of water. In most of the boilers there is a natural circulation of water the fundamental ...
Cooler water in the later water-tubes descends. Circulation is completed by the link pipes between the steam drums. [2] Circulation is more active in the earlier, hotter circuits. In the four-drum form, circulation within the middle bank may be split between a descending circuit with the first bank and an ascending circuit with the following ...