  2. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.

  3. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    S foot of water per foot of pipe; P d = pressure drop over the length of pipe in psig (pounds per square inch gauge pressure) L = length of pipe in feet; Q = flow, gpm (gallons per minute) C = pipe roughness coefficient; d = inside pipe diameter, in (inches) Note: Caution with U S Customary Units is advised. The equation for head loss in pipes ...

  4. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    where: [2] Q f = total residual flow during the test (gallons per minute); c = discharge coefficient (unitless). This is usually 1.0 if using a diffuser. If using a wand to measure the stagnation pressure, the coefficient value depends on the shape of the flow hydrant orifice.

  5. Fire hose - Wikipedia

    en.wikipedia.org/wiki/Fire_hose

    Indoor fire hose with a fire extinguisher. A fire hose (or firehose) is a high-pressure hose that carries water or other fire retardant (such as foam) to a fire to extinguish it. Outdoors, it attaches either to a fire engine, fire hydrant, or a portable fire pump. [1] Indoors, it can permanently attach to a building's standpipe or plumbing system.

  6. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    The relationship between gallons per minute (gpm) and fixture unit is not constant, but varies with the number of fixture units. For example, 1000 FU is equivalent to 220 US gallons per minute (0.014 m 3 /s) while 2000 FU represents only 330 US gallons per minute (0.021 m 3 /s), about 1.5 times the flow rate.

  7. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    The SI unit is cubic metres per second (m 3 /s). Another unit used is standard cubic centimetres per minute (SCCM). In US customary units and imperial units, volumetric flow rate is often expressed as cubic feet per second (ft 3 /s) or gallons per minute (either US or imperial definitions).

  8. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The probable intensity and extent of a fire inside the building are indicated by factors including the building use, the building height, the items contained inside the building and their arrangement. These variables are compared to tables and values expressed in the model codes. The values in these tables are based on fire tests and loss history.

  9. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    Another example would be a manufacturing facility classified as ordinary hazard group 2 where a typical design area would be 1,500 square feet (140 m 2) and the design density would be 0.2 US gallons per minute (0.76 L/min) per 1 square foot (0.093 m 2) or a minimum of 300 US gallons per minute (1,100 L/min) applied over the 1,500-square-foot ...