enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device. [1]: 287

  4. Cooper Wiring Devices - Wikipedia

    en.wikipedia.org/wiki/Cooper_Wiring_Devices

    Cooper Wiring Devices is a division of Cooper Industries and provides a range of residential, institutional and industrial grade electrical devices and wiring for consumers and building contractors. The company is the successor to both Arrow-Hart & Hegeman and Eagle Electric , both of which Cooper Industries had acquired.

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Two-wire outlets having no grounding conductor may be protected by a GFCI or one upstream of the receptacle and must be labelled "No Equipment Ground" and "GFCI Protected". Most GFCI receptacles allow the connection and provide GFCI protection for down-stream connected receptacles.

  6. Cooper Industries - Wikipedia

    en.wikipedia.org/wiki/Cooper_Industries

    Cooper Industries was an American worldwide electrical products manufacturer headquartered in Houston, Texas. Founded in 1833, the company had seven operating divisions including Bussmann electrical and electronic fuses; Crouse-Hinds and CEAG explosion-proof electrical equipment; Halo and Metalux lighting fixtures; and Kyle and McGraw-Edison power systems products.

  7. Electrical outlet tester - Wikipedia

    en.wikipedia.org/wiki/Electrical_outlet_tester

    A receptacle tester being used to check for some types of improper wiring of an outlet. For this particular tester, proper wiring is indicated by the two yellow lights. The outlet tester checks that each contact in the outlet appears to be connected to the correct wire in the building's electrical wiring. It can identify several common wiring ...

  8. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    A 120 volt combination AFCI/GFCI receptacle. Unlike circuit breakers and fuses, which only open the circuit when the current exceeds a fixed value for a fixed time, a GFCI device will interrupt electrical service when more than 4 to 6 milliamperes of current in either conductor leaks to ground. A GFCI detects an imbalance between the current in ...

  9. SAE J1939 - Wikipedia

    en.wikipedia.org/wiki/SAE_J1939

    Society of Automotive Engineers standard SAE J1939 is the vehicle bus recommended practice used for communication and diagnostics among vehicle components. Originating in the car and heavy-duty truck industry in the United States, it is now widely used in other parts of the world.