Search results
Results from the WOW.Com Content Network
The standard penetration test (SPT) is an in-situ dynamic penetration test designed to provide information on the geotechnical engineering properties of soil. This test is the most frequently used subsurface exploration drilling test performed worldwide. The test procedure is described in ISO 22476-3, ASTM D1586 [1] and Australian Standards AS ...
Dynamic load testing takes a further step in analyzing the data and computing static capacity and resistance distribution. Dynamic pile monitoring takes advantage of the fact that, for driven piles, it is possible to compute the energy delivered to the pile, compression stresses at the pile top and toe and tension stresses along the shaft.
Segmented load plates adapt to the shape of the pavement to more evenly distribute the load on uneven surfaces. The load plate diameter is typically 300 mm diameter on roads and 450 mm on airports, and the load for road testing is about 40 kN, producing about 567 kPa pressure under the load plate (50 kN / 707 kPa according to European standard).
Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...
ASTM F519 is the Standard Test Method for Mechanical Hydrogen Embrittlement Evaluation of Plating/Coating Processes and Service Environments. There are 7 different samples designs and the two most commons tests are (1) the rapid test, the Rising step load testing (RSL) method per ASTM F1624 and (2) the sustained load test, which takes 200 hours ...
It is a commonly used format produced by automatic test equipment (ATE) platforms from companies such as Cohu, Roos Instruments, Teradyne, Advantest, SPEA S.p.A, and others. STDF is a binary format, but can be converted either to an ASCII format known as ATDF or to a tab delimited text file. Decoding the STDF variable length binary field data ...
The CBR test is a penetration test in which a standard piston, with a diameter of 50 mm (1.969 in), is used to penetrate the soil at a standard rate of 1.25 mm/minute. Although the force increases with the depth of penetration, in most cases, it does not increase as quickly as it does for the standard crushed rock, so the ratio decreases.
Static load testing is an in situ type of load testing used in geotechnical investigation to determine the bearing capacity of deep foundations prior to the construction of a building. It differs from the statnamic load test and dynamic load testing in that the pressure applied to the pile is slower.