enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    Diagram symbols for pressure reduction and back pressure regulators. The conceptual difference is mainly in which side the feedback is taken from. A pressure regulator is a valve that controls the pressure of a fluid to a desired value, using negative feedback from the controlled pressure. Regulators are used for gases and liquids, and can be ...

  3. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.

  4. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...

  5. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    In addition, double-regulating balancing valves are manually set to regulate the impact of pressure changes across the system. CAV (constant air volume) systems are mainly used in offices made up of a single area (e.g. open plan), where the temperature of the supply air is varied in response to a thermostat.

  6. Pressure switch - Wikipedia

    en.wikipedia.org/wiki/Pressure_switch

    Industrial pressure switches may have a calibrated scale and pointer to show the set point of the switch. A pressure switch will have a hysteresis, that is, a differential range around its setpoint, known as the switch's deadband, inside which small changes of pressure do not influence the state of the contacts. Some types allow adjustment of ...

  7. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    After receiving an operation command, the actuator moves the valve in direction OPEN or CLOSE. When reaching the end position, an automatic switch-off procedure is started. Two fundamentally different switch-off mechanisms can be used. The controls switch off the actuator as soon as the set tripping point has been reached. This is called limit ...

  8. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  9. Static pressure - Wikipedia

    en.wikipedia.org/wiki/Static_pressure

    At least one author takes a different approach in order to avoid a need for the expression freestream static pressure. Gracey has written "The static pressure is the atmospheric pressure at the flight level of the aircraft". [15] [16] Gracey then refers to the air pressure at any point close to the aircraft as the local static pressure.