The average radiation dose from an abdominal X-ray is 0.7 millisieverts (0.0007 Sv), that from an abdominal CT scan is 8 mSv, that from a pelvic CT scan is 6 mGy, and that from a selective CT scan of the abdomen and the pelvis is 14 mGy. [7]
Recognized effects of higher acute radiation doses are described in more detail in the article on radiation poisoning.Although the International System of Units (SI) defines the sievert (Sv) as the unit of radiation dose equivalent, chronic radiation levels and standards are still often given in units of millirems (mrem), where 1 mrem equals 1/1,000 of a rem and 1 rem equals 0.01 Sv.
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass.Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmful effects), and radiology (potential beneficial effects, for example in cancer treatment).
Dose area product (DAP) is a quantity used in assessing the radiation risk from diagnostic X-ray radiography examinations and interventional procedures, like angiography.It is defined as the absorbed dose multiplied by the area irradiated, expressed in gray-centimetres squared (Gy·cm 2 [1] – sometimes the prefixed units dGy·cm 2, mGy·cm 2 or cGy·cm 2 are also used). [2]
A dose rate is quantity of radiation absorbed or delivered per unit time. It is often indicated in micrograys per hour (μGy/h) [1] or as an equivalent dose rate Ḣ T in rems per hour (rem/hr) or sieverts per hour (Sv/h). [2] [3]
For comparison, radiation levels inside the United States Capitol are 85 mrem/yr (0.85 mSv/yr), close to the regulatory limit, because of the uranium content of the granite structure. [14] The NRC sets the annual total effective dose of full body radiation, or total body radiation (TBR), allowed for radiation workers 5,000 mrem (5 rem). [15] [16]
The rep has variously been defined as 83 or 93 ergs per gram of tissue (8.3/9.3 mGy) [13] or per cc of tissue. [14] In 1953 the ICRU recommended the rad, equal to 100 erg/g as a new unit of absorbed radiation, [15] but then promoted a switch to the gray in the 1970s.
In diagnostic radiology, the F-factor is the conversion factor between exposure to ionizing radiation and the absorbed dose from that radiation. In other words, it converts between the amount of ionization in air (roentgens or, in SI units, coulombs per kilogram of absorber material) and the absorbed dose in air (rads or grays).