enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  3. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2 ) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.

  4. Continuous stirred-tank reactor - Wikipedia

    en.wikipedia.org/wiki/Continuous_stirred-tank...

    The continuous stirred-tank reactor (CSTR), also known as vat-or backmix reactor, mixed flow reactor (MFR), or a continuous-flow stirred-tank reactor (CFSTR), is a common model for a chemical reactor in chemical engineering and environmental engineering. A CSTR often refers to a model used to estimate the key unit operation variables when using ...

  5. Standard addition - Wikipedia

    en.wikipedia.org/wiki/Standard_addition

    Using the calibration curve method, the analyst can calibrate the spectrometer with a pure silver aqueous solutions, and use the calibration graph to determine the amount of silver present in the waste samples. This method, however, assumes the pure aqueous solution of silver and a photographic waste sample have the same matrix and therefore ...

  6. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    The Gran plot is based on the Nernst equation which can be written as = + ⁡ {+} where E is a measured electrode potential, E 0 is a standard electrode potential, s is the slope, ideally equal to RT/nF, and {H +} is the activity of the hydrogen ion.

  7. Custody transfer - Wikipedia

    en.wikipedia.org/wiki/Custody_transfer

    Custody transfer measurements involve measurements in pipelines, storage tanks, transportation tanks (tankers, trailers or railway tanks) - whole fuel distribution process must be traceable. In order measurements can be made in a volume or mass units (or both), so various metering methods are commonly used. [3]

  8. Reaction calorimeter - Wikipedia

    en.wikipedia.org/wiki/Reaction_calorimeter

    This method effectively measures heat loss or gain, circumventing many calibration issues associated with heat flow and power compensation calorimetry. However, it is less effective in traditional batch vessels, where significant heat shifts in the cooling/heating jacket can obscure the process's heat signal.

  9. Matrix (chemical analysis) - Wikipedia

    en.wikipedia.org/wiki/Matrix_(chemical_analysis)

    In cases with complex or unknown matrices, the standard addition method can be used. [3] In this technique, the response of the sample is measured and recorded, for example, using an electrode selective for the analyte. Then, a small volume of standard solution is added and the response is measured again. Ideally, the standard addition should ...