  2. Position error - Wikipedia

    en.wikipedia.org/wiki/Position_error

    The pitot tube supplies pressure to the airspeed indicator. Pitot pressure is equal to stagnation pressure providing the pitot tube is aligned with the local airflow, it is located outside the boundary layer, and outside the wash from the propeller.

  3. Pitot–static system - Wikipedia

    en.wikipedia.org/wiki/Pitot–static_system

    A blocked pitot tube is a pitot–static problem that will only affect airspeed indicators. [6] A blocked pitot tube will cause the airspeed indicator to register an increase in airspeed when the aircraft climbs, even though actual airspeed is constant.

  4. Pitot tube - Wikipedia

    en.wikipedia.org/wiki/Pitot_tube

    This example, from an Airbus A380, combines a pitot tube (right) with a static port and an angle-of-attack vane (left). Air-flow is right to left. Types of pitot tubes A pitot-static tube connected to a manometer Pitot tube on Kamov Ka-26 helicopter A Formula One car during testing with frames holding many pitot tubes Location of pitot tubes on ...

  5. Stagnation pressure - Wikipedia

    en.wikipedia.org/wiki/Stagnation_Pressure

    The two points of interest are 1) in the freestream flow at relative speed where the pressure is called the "static" pressure, (for example well away from an airplane moving at speed ); and 2) at a "stagnation" point where the fluid is at rest with respect to the measuring apparatus (for example at the end of a pitot tube in an airplane).

  6. Birgenair Flight 301 - Wikipedia

    en.wikipedia.org/wiki/Birgenair_Flight_301

    None of the pitot tubes were recovered so investigators were unable to determine for certain what caused the blockage. Investigators believe that the most likely culprit was the black and yellow mud dauber ( Sceliphron caementarium ), a type of solitary sphecid wasp well known to Dominican pilots, which makes a cylindrical nest out of mud and ...

  7. Talk:Pitot tube - Wikipedia

    en.wikipedia.org/wiki/Talk:Pitot_tube

    In "Review of the Pitot tube", R. G. Folsom, Michigan, wrote : "The name "Pitot tube" has been applied to two general classifications of instruments, the first being a tube that measures the impact or total pressures only, and the second a combined tube that measures both the impact and the static pressures with a single primary instrument ...

  8. Venturi effect - Wikipedia

    en.wikipedia.org/wiki/Venturi_effect

    A flow of air through a pitot tube Venturi meter, showing the columns connected in a manometer and partially filled with water. The meter is "read" as a differential pressure head in cm or inches of water. Video of a Venturi meter used in a lab experiment Idealized flow in a Venturi tube

  9. Pitot pressure - Wikipedia

    en.wikipedia.org/wiki/Pitot_pressure

    The stationary fluid can be connected to a pressure-measuring device, or used in various devices. For subsonic flow, pitot pressure is equal to the stagnation pressure (or total pressure) of the flow, and hence the term pitot pressure is often used interchangeably with these other terms. For supersonic flow, however, pitot pressure is the ...