enow.com Web Search

  1. Ads

    related to: transformer rating in kva list
    • Sell Your Transformer

      Get an offer for your transformer

      We buy new and used transformers

    • Padmount

      Request a quote for a padmount

      In stock padmount transformers

    • Medium Voltage Dry-Type

      Request a quote for a mv dry-type

      In stock mv dry-type transformers

    • News

      Check Out The Latest News About

      Maddox Industrial Transformer.

Search results

  1. Results from the WOW.Com Content Network
  2. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design. They usually don't ...

  3. Orders of magnitude (current) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(current)

    400 V low voltage secondary side distribution transformer with primary 12 kV; 200 kVA (up to 1000 kVA also common) [7] 10 3: 2 kA 10.5 kV secondary side from an electrical substation with primary 115 kV; 63 MVA [8] 9.3 kA 2.7V, Ultracapacitor short circuit current [9] 10 4: 25 kA Lorentz force can crusher pinch [10] 30 kA Typical lightning ...

  4. Low-voltage network - Wikipedia

    en.wikipedia.org/wiki/Low-voltage_network

    North American distribution transformers must be therefore placed much closer to consumers, and are smaller (25–50 kVA), while European ones can cover larger areas and thus have higher ratings (300–1000 kVA); only the remote rural areas in European design are served by single-phase transformers.

  5. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  6. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Transformers step down transmission voltages, 35 kV or more, down to primary distribution voltages. These are medium voltage circuits, usually 600–35 000 V. [1] From the transformer, power goes to the busbar that can split the distribution power off in multiple directions. The bus distributes power to distribution lines, which fan out to ...

  7. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    Pad-mounted transformers are made in power ratings from around 15 to around 5000 kVA and often include built-in fuses and switches. Primary power cables may be connected with elbow connectors, which can be operated when energized using a hot stick and allows for flexibility in repair and maintenance.

  8. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    By choosing the base quantities in this manner, the transformer can be effectively removed from the circuit as described above. For example: Take a transformer that is rated at 10 kVA and 240/100 V. The secondary side has an impedance equal to 1∠0° Ω. The base impedance on the secondary side is equal to:

  9. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    The oil is cooled by the outside of the tank in small ratings, and by an air-cooled radiator in larger ratings. Where a higher rating is required, or where the transformer is in a building or underground, oil pumps circulate the oil, fans may force air over the radiators, or an oil-to-water heat exchanger may also be used. [9]

  1. Ads

    related to: transformer rating in kva list