Minor losses in pipe flow are a major part in calculating the flow, pressure, or energy reduction in piping systems. Liquid moving through pipes carries momentum and energy due to the forces acting upon it such as pressure and gravity.
In more practical terms, the flow coefficient C v is the volume (in US gallons) of water at 60 °F (16 °C) that will flow per minute through a valve with a pressure drop of 1 psi (6.9 kPa) across the valve. The use of the flow coefficient offers a standard method of comparing valve capacities and sizing valves for specific applications that is ...
The proportionality coefficient is the dimensionless "Darcy friction factor" or "flow coefficient". This dimensionless coefficient will be a combination of geometric factors such as π, the Reynolds number and (outside the laminar regime) the relative roughness of the pipe (the ratio of the roughness height to the hydraulic diameter).
Certain valves are provided with an associated flow coefficient, commonly known as C v or K v. The flow coefficient relates pressure drop, flow rate, and specific gravity for a given valve. [10] Many empirical calculations exist for calculation of pressure drop, including: Darcy–Weisbach equation, to calculate pressure drop in a pipe
Hydraulic spool valves: These valves rely on precise clearances to control the flow of hydraulic fluid. The clearance between the spool and valve body affects the valve's responsiveness, leakage rate, and overall performance. Different types of spool valves, such as two-way, three-way, and four-way valves, have varying clearance requirements.
h f = head loss in meters (water) over the length of pipe; L = length of pipe in meters; Q = volumetric flow rate, m 3 /s (cubic meters per second) C = pipe roughness coefficient; d = inside pipe diameter, m (meters) Note: pressure drop can be computed from head loss as h f × the unit weight of water (e.g., 9810 N/m 3 at 4 deg C)
ΔE is the fluid's mechanical energy loss, ξ is an empirical loss coefficient, which is dimensionless and has a value between zero and one, 0 ≤ ξ ≤ 1, ρ is the fluid density, v 1 and v 2 are the mean flow velocities before and after the expansion. In case of an abrupt and wide expansion, the loss coefficient is equal to one. [1]
The three values chosen for friction loss correspond to, in US units inch water column per 100 feet, 0.01, .03, and 0.1. Note that, in approximation, for a given value of flow volume, a step up in duct size (say from 100mm to 120mm) will reduce the friction loss by a factor of 3.