enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.

  3. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.

  4. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.

  5. Formwork - Wikipedia

    en.wikipedia.org/wiki/Formwork

    Formwork tables in use at a building site with more complicated structural features. Crane fork or elevator handled: By this approach the tables are limited in size and weight. Typical widths are between 6 and 10 feet (1.8 and 3.0 m), typical lengths are between 12 and 20 feet (3.7 and 6.1 m), though table sizes may vary in size and form.

  6. Grade beam - Wikipedia

    en.wikipedia.org/wiki/Grade_beam

    Grade beam. A grade beam or grade beam footing is a component of a building's foundation. It consists of a reinforced concrete beam that transmits the load from a bearing wall into spaced foundations such as pile caps or caissons. [1] It is used in conditions where the surface soil's load-bearing capacity is less than the anticipated design loads.

  7. T-beam - Wikipedia

    en.wikipedia.org/wiki/T-beam

    Unlike an I-beam, a T-beam lacks a bottom flange, which carries savings in terms of materials, but at the loss of resistance to tensile forces. [5] T- beam designs come in many sizes, lengths and widths to suit where they are to be used (eg highway bridge, underground parking garage) and how they have to resist the tension, compression and shear stresses associated with beam bending in their ...

  8. Reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete

    The first reinforced concrete building in Southern California was the Laughlin Annex in downtown Los Angeles, constructed in 1905. [16] [17] In 1906, 16 building permits were reportedly issued for reinforced concrete buildings in the City of Los Angeles, including the Temple Auditorium and 8-story Hayward Hotel. [18] [19]

  9. Roller-compacted concrete - Wikipedia

    en.wikipedia.org/wiki/Roller-compacted_concrete

    The rebuilt upper reservoir of the Taum Sauk plant, nearing completion in this photo, is the largest RCC dam in North America. [1]Roller-compacted concrete (RCC) or rolled concrete (rollcrete) is a special blend of concrete that has essentially the same ingredients as conventional concrete but in different ratios, and increasingly with partial substitution of fly ash for portland cement. [2]