Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...
Smoke dampers can be activated by the fire alarm system, usually initiated by smoke detectors, or interlocked with a fire suppression system. Smoke dampers close by an electric or pneumatic actuator, or a spring actuator, and can be either manually reset or driven open on a reset signal to the electric or pneumatic actuator.
A damper or adjustable louver designed to augment the ventilation of a space during a fire. split system A split system is the combination of an outdoor unit and an indoor unit. This is the most common type of system. superheat The number of degrees a vapor is above its boiling point at a specific pressure. subcooling
AMCA Publication 502 - Damper Application Manual for Heating, Ventilating, and Air Conditioning is a guide to understanding the various types of dampers available and items to be considered for their proper use. Dampers classified as fire dampers, heat dampers, and smoke dampers are not included.
Vertically mounted fire dampers are gravity operated, while horizontal fire dampers are spring powered. A fire damper's most important feature is a mechanical fusible link which is a piece of metal that will melt or break at a specified temperature. This allows the damper to close (either from gravity or spring power), effectively sealing the ...
This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...
A short piece of fire hose, usually 10 to 20 feet (6.1 m) long, of large diameter, greater than 2.5 inches (64 mm) and as large as 6 inches (150 mm), used to move water from a fire hydrant to the fire engine, when the fire apparatus is parked close to the hydrant. Solid stream A fire-fighting water stream emitted from a smooth-bore nozzle.
Dampers can also help adjust a HVAC system for seasonal use. [7] During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [ 7 ] (