Search results

  1. Results from the WOW.Com Content Network
  2. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    ANSI C57.12.26 (Withdrawn) – Standard for Transformers-Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers for Use with Separable Insulated High-Voltage Connectors, 34,500 Grd/19,920 Volts and Below; 2500 kVA and Smaller

  3. Spot network substation - Wikipedia

    en.wikipedia.org/wiki/Spot_Network_Substation

    Some of New York City's downtown areas are powered by submersible network transformers of 500 to 2,500 kVA. Usually these transformers are in vaults below metal grates in the sidewalks. [3] Urban (spot) network transformer substations can be used to make interconnected distribution networks to serve a single facility.

  4. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    Set sizes range from 8 to 30-kW (also 8 to 30-kVA single phase) for homes, small shops, and offices, with the larger industrial generators from 8-kW (11 kVA) up to 2,000-kW (2,500-kVA three phase) used for office complexes, factories, and other industrial facilities. A 2,000-kW set can be housed in a 40 ft (12 m) ISO container with a fuel tank ...

  5. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Commercial and distribution transformers rated up to say 2,500 kVA are usually designed with short-circuit impedances of between about 3% and 6% and with a corresponding / ratio (winding reactance/winding resistance ratio) of between about 3 and 6, which defines the percent secondary voltage variation between no-load and full load.

  6. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design.

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A leakage transformer, also called a stray-field transformer, has a significantly higher leakage inductance than other transformers, sometimes increased by a magnetic bypass or shunt in its core between primary and secondary, which is sometimes adjustable with a set screw. This provides a transformer with an inherent current limitation due to ...