If boric acid (or some other weak acid) was used, direct acid–base titration is done with a strong acid of known concentration. HCl or H 2 SO 4 can be used. Indirect back titration is used instead if strong acids were used to make the standard acid solution: strong base of known concentration (like NaOH) is used to neutralize the solution. In ...
Back titration is a titration done in reverse; instead of titrating the original sample, a known excess of standard reagent is added to the solution, and the excess is titrated. A back titration is useful if the endpoint of the reverse titration is easier to identify than the endpoint of the normal titration, as with precipitation reactions
Fig. 15. Titration plot of back-titration of excess EDTA with Cu(II) in NH 3 /NH 4 Cl buffered solution. Direct EDTA titrations with metal ions are possible when reaction kinetics are fast, for example zinc, copper, calcium and magnesium. However, with slower reaction kinetics such as those exhibited by cobalt and nickel, back-titrations are used.
A typical titration curve of a diprotic acid, oxalic acid, titrated with a strong base, sodium hydroxide.Both equivalence points are visible. Titrations are often recorded on graphs called titration curves, which generally contain the volume of the titrant as the independent variable and the pH of the solution as the dependent variable (because it changes depending on the composition of the ...
Some examples of primary standards for titration of solutions, based on their high purity, are provided: [4] Arsenic trioxide for making sodium arsenite solution for standardisation of sodium periodate solution (until Ph. Eur. 3, Appendix 2001 also for iodine and cerium(IV) sulfate solutions, since Ph. Eur. 4, 2002 standardised by sodium ...
Advantages of Coulometric Titration Coulometric titration has the advantage that constant current sources for the generation of titrants are relatively easy to make. The electrochemical generation of a titrant is much more sensitive and can be much more accurately controlled than the mechanical addition of titrant using a burette drive.
The term also has two other, conflicting meanings. In titration, the titer is the ratio of actual to nominal concentration of a titrant, e.g. a titer of 0.5 would require 1/0.5 = 2 times more titrant than nominal. This is to compensate for possible degradation of the titrant solution.
For a strong acid-strong base titration monitored by pH, we have at any i'th point in the titration = [+] [] where K w is the water autoprotolysis constant.. If titrating an acid of initial volume and concentration [+] with base of concentration [], then at any i'th point in the titration with titrant volume ,