Shunt resistor. The common and simple approach to current sensing is the use of a shunt resistor. That the voltage drop across the shunt is proportional to its current flow, i.e. ohm's law, makes the low resistance current shunt a very popular choice for current measurement system with its low cost and high reliability.
As an introduction to the next chapter, this figure shows that the term "shunt resistor" should be understood in the context of what it shunts. In this example the resistor R L would be understood as "the shunt resistor" (to the load L), because this resistor would pass current around the load L. R L is connected in parallel with the load L.
To measure larger currents, a resistor called a shunt is placed in parallel with the meter. The resistances of shunts is in the integer to fractional milliohm range. Nearly all of the current flows through the shunt, and only a small fraction flows through the meter. This allows the meter to measure large currents.
Current sense amplifiers (also called current shunt amplifiers) are special-purpose amplifiers that output a voltage proportional to the current flowing in a power rail. . They utilize a "current-sense resistor" to convert the load current in the power rail to a small voltage, which is then amplified by the current-sense amplifi
A voltmeter is then connected in parallel to the resistors and the measured values of voltage for each load state can be used to calculate the load regulation as given in the equation above. Programmable loads are typically used to automate the measurement of load regulation.
Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...
Current can also be measured without breaking the circuit by detecting the magnetic field associated with the current. Devices, at the circuit level, use various techniques to measure current: Shunt resistors [18] Hall effect current sensor transducers; Transformers (however DC cannot be measured) Magnetoresistive field sensors [19] Rogowski ...
Such meters are often calibrated to read some other quantity that can be converted to a current of that magnitude. The use of current dividers, often called shunts, allows a meter to be calibrated to measure larger currents. A meter can be calibrated as a DC voltmeter if the resistance of the coil is known by calculating the voltage required to ...