For air with a heat capacity ratio =, then =; other gases have in the range 1.09 (e.g. butane) to 1.67 (monatomic gases), so the critical pressure ratio varies in the range < / <, which means that, depending on the gas, choked flow usually occurs when the downstream static pressure drops to below 0.487 to 0.587 times the absolute pressure in ...
Flare stack at the Shell Haven refinery in England. A gas flare, alternatively known as a flare stack, flare boom, ground flare, or flare pit, is a gas combustion device used in places such as petroleum refineries, chemical plants and natural gas processing plants, oil or gas extraction sites having oil wells, gas wells, offshore oil and gas rigs and landfills.
The purpose is to prevent 'loss of containment' of volatile liquids and gases. Blowdown from several systems may be combined in a blowdown header prior to the stack. A knock-out pot may be provided at the base of the stack to remove any liquids. Blowdown stacks may either be ignited (like a flare) or un-ignited (a ‘cold’ vent).
Fig. 1. Manifold arrangement for flow distribution. Traditionally, most of theoretical models are based on Bernoulli equation after taking the frictional losses into account using a control volume (Fig. 2). The frictional loss is described using the Darcy–Weisbach equation. One obtains a governing equation of dividing flow as follows: Fig. 2.
A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.
Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.
Oscillating poppet valve on one of Chapelon's rebuilt 4-6-2 locomotives. Poppet valves have been used on steam locomotives, often in conjunction with Lentz or Caprotti valve gear. British examples include: LNER Class B12; LNER Class D49; LNER Class P2; LMS Stanier Class 5 4-6-0; BR standard class 5; BR standard class 8 71000 Duke of Gloucester.
The most common flare fitting standards in use today are the 45° SAE flare [2] [3],the 37° JIC flare, and the 37° AN flare. For high pressure, flare joints are made by doubling the tube wall material over itself before the bell end is formed. The double flare avoids stretching the cut end where a single flare may crack.