However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm 2). The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor.
The conversion factor from square mils to circular mils is therefore 4/ π cmil per square mil: 4 π c m i l m i l 2 . {\displaystyle {\rm {{\frac {4}{\pi }}{\frac {cmil}{mil^{2}}}.}}} The formula for the area of an arbitrary circle in circular mils can be derived by applying this conversion factor to the standard formula for the area of a ...
A table of the gauge numbers and wire diameters is shown below. [1] [2] The basis of the system is the thou (or mil in US English), or 0.001 in. Sizes are specified as wire diameters, stated in thou and tenths of a thou (mils and tenths). The wire diameter diminishes with increasing size number.
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it The first attempt to adopt a geometrical system was made by Messrs Brown & Sharpe in 1855.
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
The table below lists units supported by {{convert}}. More complete lists are linked for each dimension. For a complete list of all dimensions, see full list of units. {{Convert}} uses unit-codes, which are similar to, but not necessarily exactly the same as, the usual written abbreviation for a given unit. These unit-codes are displayed in ...
Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...
For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...