Search results
Results from the WOW.Com Content Network
It was originally thought of as having a benign prognosis. In the Framingham Heart Study, however, the presence of a prolonged PR interval or first degree AV block doubled the risk of developing atrial fibrillation, tripled the risk of requiring an artificial pacemaker, and was associated with a small increase in mortality. This risk was ...
Atrial fibrillation (AF, AFib or A-fib) is an abnormal heart rhythm (arrhythmia) characterized by rapid and irregular beating of the atrial chambers of the heart. [ 11 ] [ 12 ] It often begins as short periods of abnormal beating , which become longer or continuous over time. [ 4 ]
Carotid sinus syncope is due to pressure on the carotid sinus in the neck. [2] The underlying mechanism involves the nervous system slowing the heart rate and dilating blood vessels, resulting in low blood pressure and thus not enough blood flow to the brain. [2] Diagnosis is based on the symptoms after ruling out other possible causes. [3]
There are two major classes of cardiac fibrillation: atrial fibrillation and ventricular fibrillation. Atrial fibrillation is an irregular and uncoordinated contraction of the cardiac muscle of atria. It can be a chronic condition, usually treated with anticoagulation and sometimes with conversion to normal sinus rhythm.
However, atrial flutter is more resistant to correction with such medications than atrial fibrillation. [1] For example, although the class III antiarrhythmic agent ibutilide is an effective treatment for atrial flutter, rates of recurrence after treatment are quite high (70–90%). [ 1 ]
Ashman beats are described as wide complex QRS complexes that follow a short R-R interval preceded by a long R-R interval. [3] This short QRS complex typically has a right bundle branch block morphology and represents an aberrantly conducted complex that originates above the AV node, rather than a complex that originates in either the right or left ventricle.
The ICD-10 Procedure Coding System (ICD-10-PCS) is a US system of medical classification used for procedural coding.The Centers for Medicare and Medicaid Services, the agency responsible for maintaining the inpatient procedure code set in the U.S., contracted with 3M Health Information Systems in 1995 to design and then develop a procedure classification system to replace Volume 3 of ICD-9-CM.
Congestive heart failure patients that were implanted with an ICD had an all-cause death risk 23% lower than placebo and an absolute decrease in mortality of 7.2 percentage points after five years in the overall population. 1 Reporting in 1999, the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial consisted of 1,016 patients, and ...