enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Feedwater heater - Wikipedia

    en.wikipedia.org/wiki/Feedwater_heater

    A Rankine cycle with two steam turbines and a single open feedwater heater. A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating boiler. [1] [2] [3] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system ...

  3. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Both effects will reduce the pipe's overall thermal efficiency when used as a heat exchanger. Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main ...

  4. Economizer - Wikipedia

    en.wikipedia.org/wiki/Economizer

    In this context they are often referred to as feedwater heaters and heat the condensate from turbines before it is pumped to the boilers. Economizers are commonly used as part of a heat recovery steam generator (HRSG) in a combined cycle power plant. In an HRSG, water passes through an economizer, then a boiler and then a superheater. The ...

  5. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).

  6. Water-tube boiler - Wikipedia

    en.wikipedia.org/wiki/Water-tube_boiler

    Pulp and Paper manufacturing plants; Refining units; Besides, they are frequently employed in power generation plants where large quantities of steam (ranging up to 500 kg/s) having high pressures i.e. approximately 16 megapascals (160 bar) and high temperatures reaching up to 550 °C are generally required.

  7. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    Feedwater pumps range in size up to many kilowatts and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feedwater pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam ...

  8. Franco-Crosti boiler - Wikipedia

    en.wikipedia.org/wiki/Franco-Crosti_boiler

    British 9F 92024 with Crosti boiler, showing secondary smokebox door and side-mounted chimney Schematic diagram of a Franco–Crosti boiler with single feedwater heater. The Franco–Crosti boiler is a type of boiler used for steam locomotives. It was designed in the 1930s by Attilio Franco and Dr Piero Crosti. [1]

  9. Air preheater - Wikipedia

    en.wikipedia.org/wiki/Air_preheater

    Schematic diagram of typical coal-fired power plant steam generator highlighting the air preheater (APH) location. An air preheater is any device designed to heat air before another process (for example, combustion in a boiler), with the primary objective of increasing the thermal efficiency of the process.