Search results
Results from the WOW.Com Content Network
The ratio of the "sample spectrum" to the "background spectrum" is directly related to the sample's absorption spectrum. Accordingly, the technique of "Fourier-transform spectroscopy" can be used both for measuring emission spectra (for example, the emission spectrum of a star), and absorption spectra (for example, the absorption spectrum of a ...
The plot for vapor is a transformation of data Synthetic spectrum for gas mixture ' Pure H 2 O ' (296K, 1 atm) retrieved from Hitran on the Web Information System. [6] Liquid water absorption spectrum across a wide wavelength range [missing source] The absorption of electromagnetic radiation by water depends on the state of the water.
SDBS includes 14700 1 H NMR spectra and 13000 13 C NMR spectra as well as FT-IR, Raman, ESR, and MS data. The data are stored and displayed as an image of the processed data. Annotation is achieved by a list of the chemical shifts correlated to letters which are also used to label a molecular line drawing.
Typically 2–50 mg of a substance is required to record a decent-quality NMR spectrum. The NMR method is non-destructive, thus the substance may be recovered. To obtain high-resolution NMR spectra, solid substances are usually dissolved to make liquid solutions, although solid-state NMR spectroscopy is also possible.
Bruker 700 MHz nuclear magnetic resonance (NMR) spectrometer. Nuclear Magnetic Resonance (NMR) basic principles. Nuclear magnetic resonance (NMR) is a physical phenomenon in which nuclei in a strong constant magnetic field are disturbed by a weak oscillating magnetic field (in the near field [1]) and respond by producing an electromagnetic signal with a frequency characteristic of the magnetic ...
The FT-IR spectra were recorded using a Nicolet 170SX or a JASCO FT/IR-410 spectrometer. For spectra recorded in the Nicolet spectrometer, the data were stored at intervals of 0.5 cm −1 in the 4,000 – 2,000 cm −1 region and of 0.25 cm −1 in the 2,000 – 400 cm −1 region and the spectral resolution was 0.25 cm −1.
This time-domain signal (a sinusoid) is typically digitised and then Fourier transformed in order to obtain a frequency spectrum of the NMR signal i.e. the NMR spectrum. [2] The duration of the NMR signal is ultimately limited by T 2 relaxation, but mutual interference of the different NMR frequencies present also causes the signal to be damped ...
The shape of lines in a nuclear magnetic resonance (NMR) spectrum is determined by the process of free induction decay. This decay is approximately exponential, so the line shape is Lorentzian. [10] This follows because the Fourier transform of an exponential function in the time domain is a Lorentzian in the frequency domain.