Search results
Results from the WOW.Com Content Network
Boiler water is treated to prevent scaling, corrosion, foaming, and priming. Chemicals are put into boiler water through the chemical feed tank to keep the water within chemical range. These chemicals are mostly oxygen scavengers and phosphates. The boiler water also has frequent blowdowns in order to keep the chloride content down.
Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam. The term may also be applied to raw water intended for use in boilers, treated boiler feedwater , steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.
A steam boiler evaporates liquid water to form steam, or gaseous water, and requires frequent replenishment of boiler feedwater for the continuous production of steam required by most boiler applications. Water is a capable solvent, and will dissolve small amounts of solids from piping and containers including the boiler.
Oxygenated Treatment (Neutral Water Treatment) Oxygenated Treatment (Combined Water Treatment) Feedwater system piping: ferrus or mixed metallurgy (e.g. copper feedwater train) all-ferrous metallurgy: all-ferrous metallurgy: all-ferrous metallurgy Dissolved oxygen level < 10 ppb: 1 to 10 ppb: 30-50 ppb (drum), 30-150 (supercritical)
A means had to be provided, of course, to put the initial charge of water into the boiler (before steam power was available to operate the steam-powered feedwater pump). The pump was often a positive displacement pump that had steam valves and cylinders at one end and feedwater cylinders at the other end; no crankshaft was required.
Should the boiler not have an oxygen-content analyzer, a high level in the boiler chlorides may indicate the vent valve not being far enough open. Some designs may include a vent condenser to trap and recover any water entrained in the vented gas. The vent line usually includes a valve and just enough steam is allowed to escape with the vented ...
A quantitative method to determine the amount of phosphate present in samples, such as boiler feedwater, is as follows. A measured amount of boiler water is poured into a mixing tube and ammonium heptamolybdate reagent is added. The tube is then stoppered and vigorously shaken.
The main focus is finances of farming, production practices, and resource use. Seventeen total states are sampled every 5–6 years per livestock type, with the most recent surveys distributed to broiler farmers in 2006 and 2011. There was one question about utilization of antibiotics in poultry food or water, excluding use for illness ...