Search results
Results from the WOW.Com Content Network
Pourbaix diagram of iron. [1] The Y axis corresponds to voltage potential. In electrochemistry, and more generally in solution chemistry, a Pourbaix diagram, also known as a potential/pH diagram, E H –pH diagram or a pE/pH diagram, is a plot of possible thermodynamically stable phases (i.e., at chemical equilibrium) of an aqueous electrochemical system.
The measurement of pH can become difficult at extremely acidic or alkaline conditions, such as below pH 2.5 (ca. 0.003 mol/dm 3 acid) or above pH 10.5 (above ca. 0.0003 mol/dm 3 alkaline). This is due to the breakdown of the Nernst equation in such conditions when using a glass electrode. Several factors contribute to this problem.
The values below are standard apparent reduction potentials (E°') for electro-biochemical half-reactions measured at 25 °C, 1 atmosphere and a pH of 7 in aqueous solution. [1] [2] The actual physiological potential depends on the ratio of the reduced (Red) and oxidized (Ox) forms according to the Nernst equation and the thermal voltage.
The determination of the formal reduction potential at pH = 7 for a given biochemical half-reaction requires thus to calculate it with the corresponding Nernst equation as a function of pH. One cannot simply apply an offset of -414 mV to the E h value (SHE) when the ratio h ⁄ z differs from 1.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
A typical titration curve of a diprotic acid, oxalic acid, titrated with a strong base, sodium hydroxide.Both equivalence points are visible. Titrations are often recorded on graphs called titration curves, which generally contain the volume of the titrant as the independent variable and the pH of the solution as the dependent variable (because it changes depending on the composition of the ...
To use potentiometric (e.m.f.) measurements in monitoring the + concentration in place of readings, one can trivially set [+] = and apply the same equations as above, where is the offset correction /, and is a slope correction / (1/59.2 pH units/mV at 25°C), such that replaces .
Buffer capacity falls to 33% of the maximum value at pH = pK a ± 1, to 10% at pH = pK a ± 1.5 and to 1% at pH = pK a ± 2. For this reason the most useful range is approximately pK a ± 1. When choosing a buffer for use at a specific pH, it should have a pK a value as close as possible to that pH. [2]