Search results
Results from the WOW.Com Content Network
A foundation is a connecting link between the structure proper and the ground which supports it. The bearing strength characteristics of foundation soil are major design criterion for civil engineering structures. In nontechnical engineering, bearing capacity is the capacity of soil to support the loads applied to the ground.
Live loads, sometimes also referred to as probabilistic loads, include all the forces that are variable within the object's normal operation cycle not including construction or environmental loads. Roof and floor live loads are produced during maintenance by workers, equipment and materials, and during the life of the structure by movable ...
Another common type of shallow foundation is the slab-on-grade foundation where the weight of the structure is transferred to the soil through a concrete slab placed at the surface. Slab-on-grade foundations can be reinforced mat slabs, which range from 25 cm to several meters thick, depending on the size of the building, or post-tensioned ...
For normal weight concrete (defined as concrete with a w c of 150 lb/ft 3 and subtracting 5 lb/ft 3 for steel) E c is permitted to be taken as ′. The publication used by structural bridge engineers is the AASHTO Load and Resistance Factor Design Manual, or
In many domestic and industrial buildings, a thick concrete slab supported on foundations or directly on the subsoil, is used to construct the ground floor. These slabs are generally classified as ground-bearing or suspended. A slab is ground-bearing if it rests directly on the foundation, otherwise the slab is suspended. [3]
Slab-on-grade or floating slab foundations are a structural engineering practice whereby the concrete slab that is to serve as the foundation for the structure is formed from a mold set into the ground. The concrete is then placed into the mold, leaving no space between the ground and the structure.
Static load testing is an in situ type of load testing used in geotechnical investigation to determine the bearing capacity of deep foundations prior to the construction of a building. It differs from the statnamic load test and dynamic load testing in that the pressure applied to the pile is slower.
Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.