During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [7] (The return should be efficient enough to draw off the cooler air.) [10] [11]
At a certain plane in the room, the airflow rate returned to the upper zone is equal to the supply air. The plane divides the room into occupied zone and upper zone and leads to thermal stratification: the hot and contaminated air is concentrated in the upper zone, and the air in the occupied zone is cool and fresh. [2]
Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.
For example, at a given time one building may be utilizing chilled water for air conditioning and the warm water it returns may be used in another building for heating, or for the overall heating-portion of the DHC network (likely with energy added to boost the temperature). [3] [4] [5]
Supply diffusers in the ceiling are fed by fan coil units in the ceiling void or by air handling units in a remote plant room. The fan coil or handling unit takes in return air from the ceiling void and mix this with fresh air and cool, or heat it, as required to achieve the room design conditions. This arrangement is known as 'conventional ...
Combines hydronic (hot water) heating with a forced air delivery; Heat is produced via combustion of fuel (gas/propane/oil) in a boiler; A heat exchanger (hydronic coil) is placed in the air handler similar to the refrigerant coil in a Heat Pump system or a Central AC. Copper is often specified in supply and return manifolds and in tube coils.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The study of the behavior of air-water vapor mixtures. Water vapor plays an important role in energy transfer and human comfort in HVAC design. rooftop unit (RTU) A packaged unit that controls both heating and air conditioning. An air handler typically refers to a unit that provides a fan to support either heating or cooling. radiant ceiling panels