Search results
Results from the WOW.Com Content Network
In 2009, it launched Trophon, a unique, automated technology for the high-level disinfection of intracavity and surface ultrasound probes. In 2010 Nanosonics warned that it had become aware of a substandard component being used in the production of its Tryphon EPR ultrasound disinfectant device and had moved to rectify the problem.
The PA probe consists of many small ultrasonic transducers, each of which can be pulsed independently.By varying the timing, for instance by making the pulse from each transducer progressively delayed going up the line, a pattern of constructive interference is set up that results in radiating a quasi-plane ultrasonic beam at a set angle depending on the progressive time delay.
An ultrasonic horn (also known as acoustic horn, sonotrode, acoustic waveguide, ultrasonic probe) is a tapering metal bar commonly used for augmenting the oscillation displacement amplitude provided by an ultrasonic transducer operating at the low end of the ultrasonic frequency spectrum (commonly between 15 and 100 kHz).
The transducer may be used in contact with the skin, as in fetal ultrasound imaging, or inserted into a body opening such as the rectum or vagina. Clinicians who perform ultrasound-guided procedures often use a probe positioning system to hold the ultrasonic transducer. [9] Compared to other medical imaging modalities, ultrasound has several ...
Step 1: The UT probe is placed on the root of the blades to be inspected with the help of a special borescope tool (video probe). Step 2: Instrument settings are input. Step 3: The probe is scanned over the blade root. In this case, an indication (peak in the data) through the red line (or gate) indicates a good blade; an indication to the left ...
As an ultrasonic testing (UT) method, EMAT has all the advantages of UT compared to other NDT methods. Just like piezoelectric UT probes, EMAT probes can be used in pulse-echo, pitch-catch, and through-transmission configurations. EMAT probes can also be assembled into phased array probes, delivering focusing and beam steering capabilities. [6]
The ultrasound catheter tip is slid in over the guidewire and positioned, using angiography techniques so that the tip is at the farthest away position to be imaged. The sound waves are emitted from the catheter tip, are usually in the 20-40 MHz range, and the catheter also receives and conducts the return echo information out to the external ...
Ultrasonic cavitation device is a surgical device using low frequency ultrasound energy to dissect or fragment tissues with low fiber content. It is basically an ultrasound probe (acoustic vibrator) combined with an aspirator device ().