enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    At set pressure the valve snaps to full lift. This can be quite violent on large pipes with significant pressure. The pressure has to drop below the set pressure in order for the piston to reseat (see blowdown in relief valve article). Modulating The pilot is designed to open gradually, so that less of the system fluid is lost during each ...

  3. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  4. Check valve - Wikipedia

    en.wikipedia.org/wiki/Check_valve

    A swing check valve (or tilting disc check valve) is a check valve in which the disc, the movable part to block the flow, swings on a hinge or trunnion, either onto the seat to block reverse flow or off the seat to allow forward flow. The seat opening cross-section may be perpendicular to the centerline between the two ports or at an angle.

  5. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  6. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    During the design stage, the diagram also provides the basis for the development of system control schemes, allowing for further safety and operational investigations, such as a Hazard and operability study (HAZOP). To do this, it is critical to demonstrate the physical sequence of equipment and systems, as well as how these systems connect.

  7. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute.

  8. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    Double check valve during normal operation Double check valve during reverse flow. A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. [1] It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air ...

  9. Instrumentation in petrochemical industries - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_in...

    Pressure in blanketed tanks is maintained by self actuating pressure control valves (PCVs). As liquid is withdrawn from the tank the pressure in the gas space falls. The blanket gas supply valve opens to maintain the pressure. As the tank fills with liquid the pressure rises and a vent gas valve open to vent gas to atmosphere or a vent system. [11]