Legionnaires' disease is a form of atypical pneumonia caused by any species of Legionella bacteria, [3] quite often Legionella pneumophila. Signs and symptoms include cough, shortness of breath, high fever, muscle pains, and headaches. [2] Nausea, vomiting, and diarrhea may also occur. [1] This often begins 2–10 days after exposure. [2]
Almost all natural water sources contain Legionella and their presence should not be taken as an indication of a problem. The tabled figures are for total aerobic plate count, cfu/ml at 30 °C (minimum 48 hours incubation) with colony count determined by the pour plate method according to ISO 6222(21) or spread plate method on yeast extract agar.
Legionella is a genus of gram-negative bacteria that can be seen using a silver stain or grown in a special media that contains cysteine, an amino acid.It is known to cause legionellosis [3] (all illnesses caused by Legionella) including a pneumonia-type illness called Legionnaires' disease and a mild flu-like illness called Pontiac fever. [3]
The temperature of tap water should not exceed 38–45 °C (100–113 °F) to prevent discomfort and scalding. [2] However, it is necessary to keep warm water at a temperature of 55–60 °C (131–140 °F) to inhibit the growth of legionella bacteria.
Legionella pneumophila, the primary causative agent for Legionnaire's disease, is an aerobic, pleomorphic, flagellated, non-spore-forming, Gram-negative bacterium. [1] [2] L. pneumophila is a intracellular parasite that preferentially infects soil amoebae and freshwater protozoa for replication.
Ionization can be an effective process to control Legionella in potable water distribution systems found in health facilities, hotels, nursing homes, and large buildings. . In 2003, ionization became the first such hospital disinfection process to have fulfilled a proposed four-step modality evaluation; by then it had been adopted by over 100 hospitals.
The presence of Legionella in commercial building water supplies is highly under-reported, as healthy people require heavy exposure to acquire infection. Legionella testing typically involves collecting water samples and surface swabs from evaporative cooling basins, shower heads, faucets/taps, and other locations where warm water collects.
Legionella pneumophila is the most common cause, but sometimes other species of Legionella bacteria also cause Legionnaires' disease. [ 15 ] [ 16 ] The terms "Philadelphia fever" and "Legion fever" appear to have been used at the time of the outbreak and for shortly thereafter, [ 17 ] although at least one 2008 source which covers disease in a ...