Overhead insulated cables are rarely used, usually for short distances (less than a kilometer). Insulated cables can be directly fastened to structures without insulating supports. An overhead line with bare conductors insulated by air is typically less costly than a cable with insulated conductors. A more common approach is "covered" line wire.
The layout of lighting in the home must consider control of lighting since this affects the wiring. For example, multiway switching is useful for corridors and stairwells so that a light can be turned on and off from two locations. Outdoor yard lighting, and lighting for outbuildings such as garages may use switches inside the home.
A three phase electric circuit terminated with a pothead Crossarms with two three phase electric circuits terminated with potheads. A pothead is a type of insulated electrical terminal used for transitioning between overhead line and underground high-voltage cable or for connecting overhead wiring to equipment like transformers. [1]
It is known variously as overhead catenary, overhead contact line (OCL), overhead contact system (OCS), overhead equipment (OHE), overhead line equipment (OLE or OHLE), overhead lines (OHL), overhead wiring (OHW), traction wire, and trolley wire. An overhead line consists of one or more wires (or rails, particularly in tunnels) situated over ...
In North America, overhead distribution systems may be three phase, four wire, with a neutral conductor. Rural distribution system may have long runs of one phase conductor and a neutral. [17] In other countries or in extreme rural areas the neutral wire is connected to the ground to use that as a return (single-wire earth return).
A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...
From there they pass through the wall of the house to the electric panel and Main Fuses or Circuit Breakers inside. In North America, the 120/240 V split phase system is used for residential service drops. [3] [4] A pole-mounted single phase distribution transformer usually provides power for one or two residences. The secondary winding of the ...