enow.com Web Search

  1. Ad

    related to: 3kva transformer amp rating chart calculator

Search results

  1. Results from the WOW.Com Content Network
  2. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    For example, a (large) UPS system rated to deliver 400,000 volt-amperes (400 kVA) at 220 volts can deliver a current of 1818 amperes (these are RMS values). VA ratings are also often used for transformers; maximum output current is then VA rating divided by nominal output voltage. [6] Transformers with the same sized core usually have the same ...

  3. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    The ratio of the voltage bases on either side of a transformer is selected to be the same as the ratio of the transformer voltage ratings. With these two rules, a per-unit impedance remains unchanged when referred from one side of a transformer to the other. This allows the ideal transformer to be eliminated from a transformer model.

  4. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  5. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design. They usually don't ...

  6. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    The CT is typically described by its current ratio from primary to secondary. For example, a 1000:1 CT provides an output current of 1 amperes when 1000 amperes flow through the primary winding. Standard secondary current ratings are 5 amperes or 1 ampere, compatible with standard measuring instruments.

  7. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.

  8. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Calculation of the required breaking capacity involves determining the supply impedance and voltage. Supply impedance is calculated from the impedance of the elements making up the supply system. Customers of an electrical supply utility can request the maximum value of prospective short-circuit current available at their point of supply.

  9. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    Power ratings are usually given in watts for real power and volt-amperes for apparent power, although for devices intended for use in large power systems, both may be given in a per-unit system. Cables are usually rated by giving their maximum voltage and their ampacity . [ 4 ]

  1. Ad

    related to: 3kva transformer amp rating chart calculator