    en.wikipedia.org/wiki/Capability_curve

    The fixed speed wind turbines without a power converter (also known as "Type 1" and "Type 2" [5]) cannot be used for voltage control. They simply absorb the reactive power (like any typical induction machine), so a switched capacitor bank is usually used to correct the power factor to unity. [7] Capability curve of a photovoltaic generator

  3. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    A leading power factor signifies that the load is capacitive, as the load supplies reactive power, and therefore the reactive component is negative as reactive power is being supplied to the circuit. If θ is the phase angle between the current and voltage, then the power factor is equal to the cosine of the angle, cos ⁡ θ {\displaystyle ...

  4. Voltage optimisation - Wikipedia

    en.wikipedia.org/wiki/Voltage_optimisation

    A low power factor would mean that the electricity supplier would effectively supply more energy than the consumer's bill would indicate, and suppliers are allowed to charge for low power factors. Reactive power is the name given to unusable power. It does no work in the electrical system, but is used to charge capacitors or produce a magnetic ...

  5. Power-voltage curve - Wikipedia

    en.wikipedia.org/wiki/Power-voltage_curve

    Power-voltage curve (also P-V curve) describes the relationship between the active power delivered to the electrical load and the voltage at the load terminals in an electric power system under a constant power factor. [1] When plotted with power as a horizontal axis, the curve resembles a human nose, thus it is sometimes called a nose curve. [2]

  6. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded. [5] For example, a (large) UPS system rated to deliver 400,000 volt-amperes (400 kVA) at 220 volts can deliver a current of 1818 amperes (these are RMS values).

  7. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:

  8. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    The effects of this modulation on voltage magnitude and phase angle is illustrated using phasor diagrams that map V R, V S, and the resistive and inductive components of V line drop. Three power factor scenarios are shown, where (a) the line serves an inductive load so the current lags receiving end voltage, (b) the line serves a completely ...

  9. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.