enow.com Web Search

  1. Ads

    related to: 3kva transformer screwfix

Search results

  1. Results from the WOW.Com Content Network
  2. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design.

  3. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    The transformers are usually rated at 5 kVA, 10 kVA, and 25 kVA. The load densities are usually below 0.5 kVA per kilometer (0.8 kVA per mile) of line. Any single customer's maximum demand will typically be less than 3.5 kVA, but larger loads up to the capacity of the distribution transformer can also be supplied.

  4. Transformer - Wikipedia

    en.wikipedia.org/wiki/Transformer

    In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits.A varying current in any coil of the transformer produces a varying magnetic flux in the transformer's core, which induces a varying electromotive force (EMF) across any other coils wound around the same core.

  5. Phase converter - Wikipedia

    en.wikipedia.org/wiki/Phase_converter

    An American Rotary Phase Converter with a Transformer. A phase converter is a device that converts electric power provided as single phase to multiple phase or vice versa. The majority of phase converters are used to produce three-phase electric power from a single-phase source, thus allowing the operation of three-phase equipment at a site that only has single-phase electrical service.

  6. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  7. Quadrature booster - Wikipedia

    en.wikipedia.org/wiki/Quadrature_booster

    400 MVA 220/155 kV phase-shifting transformer.. A phase angle regulating transformer, phase angle regulator (PAR, American usage), phase-shifting transformer, phase shifter (West coast American usage), or quadrature booster (quad booster, British usage), is a specialised form of transformer used to control the flow of real power on three-phase electric transmission networks.

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Transformer oil is flammable, so oil-filled transformers inside a building are installed in vaults to prevent spread of fire and smoke from a burning transformer. Some transformers were built to use fire-resistant PCBs , but because these compounds persist in the environment and have adverse effects on organisms, their use has been discontinued ...

  9. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    Pad-mounted transformers are made in power ratings from around 15 to around 5000 kVA and often include built-in fuses and switches. Primary power cables may be connected with elbow connectors, which can be operated when energized using a hot stick and allows for flexibility in repair and maintenance.

  1. Ads

    related to: 3kva transformer screwfix