Search results
Results from the WOW.Com Content Network
In electronics, a constant current system is one that varies the voltage across a load to maintain a constant electric current.When a component is indicated to be driven by a constant current, the driver circuit is, in essence, a current regulator and must appear to the component as a current source of suitable reliability.
Nonetheless, it is often the case that such a circuit will provide adequate performance when the specified current and load resistance are small. For example, a 5 V voltage source in series with a 4.7 kΩ resistor will provide an approximately constant current of 1 mA ± 5% to a load resistance in the range of 50 to 450 Ω.
A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...
Current mode logic (CML), or source-coupled logic (SCL), is a digital design style used both for logic gates and for board-level digital signaling of digital data. The basic principle of CML is that current from a constant current generator is steered between two alternate paths depending on whether a logic zero or logic one is being represented.
A generator in electrical circuit theory is one of two ideal elements: an ideal voltage source, or an ideal current source. [1] These are two of the fundamental elements in circuit theory. Real electrical generators are most commonly modelled as a non-ideal source consisting of a combination of an ideal source and a resistor.
Therefore, there are N-1 node voltages for a circuit with N nodes. [2]: 2-10 In principle, nodal analysis uses Kirchhoff's current law (KCL) at N-1 nodes to get N-1 independent equations. Since equations generated with KCL are in terms of currents going in and out of nodes, these currents, if their values are not known, need to be represented ...
A feature in the generator mode in parallel to the grid is that the rotor speed is higher than in the driving mode. Then active energy is being given to the grid. [1] Another disadvantage of induction motor generator is that it consumes a significant magnetizing current I0 = (20-35)%.
The curve representing the power limit for the load for the range of current and voltage magnitudes in which the load circuit may safely operate Battery chargers are the largest single application for current controlled power supplies requiring either constant-current or constant-power output characteristics.